3. The only acceptable method for outdoor or underground cable connection is the use of a suitably rated enclosure Example is the LED Logical JB3003 shown in Fig 2. Correct Installation of Inground Luminaires

(optional installation accessory is available separately by request)

4. Any type of flat cable is unsuitable for outdoor installations as it cannot professionally terminated into a glanded junction box as required.

5. The use of any type of tape or heat-shrink is no acceptable and will not provide adequate long term integrity for wet areas

Fig 2. JB3003 Junction Box

Inground Luminaire

Luminaire Housing

Concrete

Appropriately sealed Junction box

Gravel or Bluestone Layer

Sand Layer

Fig 1. General installation of Inground Luminaire

Copyright © LED Logical 2021. No permission is granted to copy, reproduce or edit this any part of this document without the express written consent of LED Logical. All rights reserved. This guide is for generic information purposes only. Please refer to your qualified architect, designer or electrical contractor before finalising any details regarding wiring and installation. www.ledlogical.com.