Industralight Project Valley Central Shopping Centre

RETAIL & DISPLAY FIT-OUTS

PROBLEM

SOLUTION

The renovation at Valley Central meant juggling many requirements at once. Medical rooms needed clinical precision. The retail spaces required downlights to showcase products and encourage buying. Carparks demanded Australian standard pedestrian safety. And storage areas had to be functionally lit. Updating LED lighting for retail success

Matching specifications and running lighting simulations

Industralight was engaged due to our wide range that can suit every space: - Many types of downlights - Large, flat panel luminaires - Exterior street and pole lighting

We matched up luminaires to spec, each having rigorous testing and proven performance. Then we reviewed the contractor’s plans and our team ran lighting simulations. Each space visualised light intensity and illuminance. This cutting-edge approach meant zero guesswork. And our customer-centric process involved contractor approval at every step.

- Surface mounted bunkers - Linear suspended options

LIGHTING SIMULATIONS

1

2

3

4

16

5

17

6

18

7

19

8

20

9

10

11

12

13

14

15

1. LIGHTING TO COMMON MALL AREAS TO BE CONTROLLED VIA EXISTING BUILDING SECURITY SYSTEM. NOTES:

PE

MDB.MALL- TENANCIES

MDB.MALL-TENANCIES

BLADE

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

WL1

WL1

WL1

WL1

WL1

WL1

A

L2

L2

D4

D4

D4

D4

D4

D4

D4

D4

D4

D4

T2

EM/SM

EM

L1

L1

L1

L1

L1

L1

L1

L1

EM

D4

D4

L

EM

D4

D4

D4

D4

D4

D4

D4

D4

L

T2

L

EM

L

L

EM

EM

D4

D4

EM

EM

L1

L1

L1

L1

L1

L1

L1

L1

L1

D4

D4 EM

D4

D4

D4

D4

D4 EM

EM

L

L

WORKS BY TENANT, NO ELECTRICAL WORKS

L1

D4

D4 D4

L

D4

D4

D4

D4

L2

L2

EM

L1

L1

L1

L1

L1

L1

L1

L1

L

L1

PHARMARCY G.02 F-CONC

MAGAIN G.03 F-CONC

NEWSAGENCY G.04 F-CONC

GOOBY GOOSE G.05 F-CONC

D3

D4

D4

D4

D4

D4 EM

D4

D4

D4

L

EM

L

EM

L

D4

L1

L

L1

L1

L1

L1

L1

L1

L1

L1

D4

D4

D4

T2

D4

D4

D4

D4

B

D4 D4

D4

D4

EM

L

EM

EM

EM/SM

EM

D4

L

D3

L1

L1

L1

D4

D4

L

L

L

D4

EM

EM

L1

L1

L1

L1

L1

EM

L1

L1

L1

EM

L1

L2

L2

L1

L

L

L1

L1

L1

EM

EM

L

L1

D4

D4

L

L1

EM

EM

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

D4

D4

EM

EM

L1

D3

L

L

EM

C

L

DENTIST G.06 F-CONC

MEDICAL CENTRE G.07 F-CONC L1

EM

L1 L1

L

L

L1

L

L

EM

L1

L1

L1

BLADE

D4

D4

MALL G.01 F-ST.01

L2

L2

L2

L2

L2

L2

L2

L2

L2

L2

L2

L1

L1

L1

L1

L1

L

EM

EM

L1

D4

D4

EM

D3

L

EM

EM

EM

EM

L1

T2

EM

L1

T2

BLADE

D4

D4

L1

L1

L1

D2

D2

D2

D2

D2

D2

D2

D2

D2

D2

L

T2

D4

L1

L

L

EM

L1

D

EM

T2

T2

D4

D4

D4

D4

D4

D4

EM

L

L1

D2

D2

D2

D2

L

D2

L1

L1

L1

L1

EM

EM

D4

D3

L1

L1

MSB G.14 F-CONC EM

EM

T2

EM

EM

D4

D4

D2

L

T2

L

L1

D4

L

L

L1

L1

EM

EM

L

L1

EM

D4

EXISTING LIGHTING TO BE RETAINED

L1

L1

EM

D2

L FEMALE G.08 F-TL.01

D4

D4

L1

EM

EM

D1

D2

D4

EM

D1

D1

EXISTING BAKERS DELIGHT EXG.02 EXISTING BAKERS DELIGHT (OUT OF SCOPE)

EM

L

HAIRDRESSER G.16 F-CONC

BARBER G.13 F-CONC

BEAUTY SHOP G.12 F-CONC

D1

D1

D4

D4

D4

D4

D4

D4

L

EXISTING FOODLAND EXG.01

L1

D2

L1

D4

L

L

PE

EM

L1

L1

L

WORKS BY OTHERS IN SEPARATE PACKAGE

D1

D1

ACCESS G.09 F-TL.01 EM

BLADE

L

D2

D2

EM

L1

L1

L1

T2

L

STORE G.15 F-CONC

EM

D4

D4

D4

L1

EM

L

L

L

D2

EM

EM

EM

D1

L

EM

D4

D4

T2

L

D1

BLADE

L1

L1

L1

L1

L1

L1

L1

D4

CLEANER G.11 F-TL.01 L1

EM

L

L1

MALE G.10 F-TL.01

D1

EM

D1

D1

T2

PE

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

D3

PROJECT

DRAWING IS NOT FOR CONSTRUCTION. DRAWING IS INTENDED TO CAPTURE THE SCOPE ONLY AND IS NOT TO REPLACE WORKSHOP DRAWINGS OR BE USED TO DEFINE FINAL DIMENSIONED LAYOUTS FOR INSTALLATION. DO NOT SCALE. REFER TO FIGURED DIMENSIONS - IN mm UNLESS OTHERWISE STATED.

CLIENT

ARCHITECT

10.500.51 2 3 4 5m SCALEBAR 1:100 TENDER

DRAWING SALANDRA HAPPY VALLEY SHOPPING CENTRE ELECTRICAL SERVICES 50 KENIHANS RD, HAPPY VALLEY, SA 5159 GROUND FLOOR PLAN - LUMINAIRE ARRANGEMENT

ERT LP GCh

Scale

Design: Drawn: Review:

No. in Set

Date

1 : 100

5 of 7

FEB 2023

TO BE PRINTED IN COLOUR THE PURPOSE OF THIS DOCUMENT IS INTENDED TO BE VIEWED OR PRINTED IN COLOUR FOR THE FULL EXTENT OF THE SCOPE OF WORKS TO BE SHOWN.

T1 TENDER ISSUE T2 TENDER ISSUE

10.02.23 LP 01.03.23 LP

Level 6, 80 Flinders Street Adelaide SA 5000 Phone: (08) 8407 9700 Email: adelaide@lucidconsulting.com.au

Drawing no.

Orig. Size

Revision

A1

LCE23816-E102

T2

REV'N

DESCRIPTION

DATE

CHK'D

1/03/2023 10:29:52 AM

© Copyright Lucid Consulting Australia

LIGHTING PLAN

5

AN LED LIGHTING PLAN TO TRANSFORM A COMMUNITY RETAIL HUB AT VALLEY CENTRAL SHOPPING CENTRE

CONSTRUCTION BY FDC

Powered by